Vibrations in buildings
Vibrations are the oscillatory motions that can be experienced by a building, usually through its floors. Vibrations are regular cyclic motions of a given frequency and amplitude, typically being vertical vibrations, although horizontal vibrations are possible.
The length of a wave vibration is measured from the beginning of one point on a wave to the same point on the next wave and is known as the frequency. This is expressed as Hertz (Hz). The height of a wave vibration is measured from the centre line and is known as the amplitude. This is expressed in metres. The larger the amplitude, the slower the wave is as it moves from peak to trough (oscillation).
The consequences of building vibrations are determined by the source of the motion, its duration, and the building’s construction and layout. They may include:
- Presenting a nuisance to occupants.
- Disturbing sensitive equipment.
- Causing fixture and fittings damage
- Damaging structural integrity.
- The consequences will be .
Vibrations that affect buildings can be produced by a variety of sources and most are felt through the floor system. Vibrations can originate directly in the floor and then travel out from the source, or can be propagated through building members from other sorces that originate in the ground or outside the building.
Internal sources include:
- HVAC equipment.
- Lift and conveyance systems.
- Fluid pumping equipment.
- Human activity, e.g. walking, dancing, aerobic exercises, etc.
External sources include:
- Seismic activity.
- Road, rail, subway systems.
- Industrial activities.
- Construction activities, e.g. demolition works.
- Wind buffeting.
As even very low amplitudes of vibration can be perceived by occupants, building designers must consider how to avoid nuisance being caused through vibration. They should also consider the structural strength to ensure it is enough to resist the peak dynamic forces acting on it. Structural members and their connections must be designed to resist such forces, and connections must be designed to ensure that fatigue does not occur due to repeated cyclic loading.
Frequency and amplitude are taken into building designers’ calculations to determine where extra stiffness is required to dampen the vibration. Damping refers to the minimising of amplitude in a vibration or mechanical energy loss.
Anticipated usage of the floors is a critical consideration that should inform the concept design. Similarly, if a building is being constructed near a busy road or above a subway system, the foundations should be carefully detailed to accommodate the likely vibrations.
During the initial design of a building, the likelihood of perceptible vibration in sensitive spaces should be carefully assessed. This is particularly important for buildings that are designed with an unusual geometry or complicated structural systems. As the complexity of a structure increases, the impact of vibration becomes more difficult to accurately predict and effectively minimise.
It is important that building designers properly consider levels of acceptable vibration at the concept design stage as it can be very difficult, and costly, to modify an existing floor to reduce its susceptibility to vibration. Remediation may require major changes to the mass, stiffness or damping of the floor system.
Vibrations are sometimes dealt with most effectively at source. For instance, machinery-induced vibrations can be minimised by using isolating mounts or motion-arresting pads. An inexpensive approach is to increase the floor loading within the building. Weight can be placed under a raised floor to minimise movement from foot traffic for instance, and dissipate vibration.
NB A vibration dose value is defined in BS6472-1(2008) as a relationship that yields a consistent assessment of vibration which correlates well with subjective response. It is used to estimate the probability of adverse comment which might be expected from human beings experiencing vibration in buildings. Consideration is given to the time of day and use made of occupied space in buildings, whether residential, office or workshop.
[edit] Related articles on Designing Buildings
Featured articles and news
Private rental sector, living standards and fuel poverty
Report from the NRH in partnership with Impact on Urban Health.
.Cold chain condensing units market update
Tracking the evolution of commercial refrigeration unit markets.
Attending a conservation training course, personal account
The benefits of further learning for professsionals.
Restoring Alexander Pope's grotto
The only surviving part of his villa in Twickenham.
International Women's Day 8 March, 2025
Accelerating Action for For ALL Women and Girls: Rights. Equality. Empowerment.
Lack of construction careers advice threatens housing targets
CIOB warning on Government plans to accelerate housebuilding and development.
Shelter from the storm in Ukraine
Ukraine’s architects paving the path to recovery.
BSRIA market intelligence division key appointment
Lisa Wiltshire to lead rapidly growing Market Intelligence division.
A blueprint for construction’s sustainability efforts
Practical steps to achieve the United Nations Sustainable Development Goals.
Timber in Construction Roadmap
Ambitious plans from the Government to increase the use of timber in construction.
ECA digital series unveils road to net-zero.
Retrofit and Decarbonisation framework N9 launched
Aligned with LHCPG social value strategy and the Gold Standard.
Competence framework for sustainability
In the built environment launched by CIC and the Edge.
Institute of Roofing members welcomed into CIOB
IoR members transition to CIOB membership based on individual expertise and qualifications.
Join the Building Safety Linkedin group to stay up-to-date and join the debate.
Government responds to the final Grenfell Inquiry report
A with a brief summary with reactions to their response.
Comments
[edit] To make a comment about this article, click 'Add a comment' above. Separate your comments from any existing comments by inserting a horizontal line.